Default:
Enabled
Valid range:
Enabled/Disabled
Normal Quality
When this option is enabled, the camera captures lower res-
olution images (160 x 128 dpi).
Default:
Disabled
Valid range:
Enabled/Disabled
Audio (mic)
This option is used to enable/disable the built-in microphone
on the device.
Default:
Disabled
Valid range:
Enabled/Disabled
4.7.10 Wireless PIR (NO CAM) Con-
figurations
The following sections are used to program wireless motion
detectors.
Device Enable/Disable
This option is used to enable and disable the wireless
device.
Default:
Enabled
Valid range:
Enabled/Disabled
Device Partition Assignment
This option is used to enable and disable the wireless
device.
Default:
Valid range:
Chime Tone
This option is used to select the tone emitted by the device
when the zone is tripped.
Default:
Beeps
Valid range:
Beeps, Bing Bing, Ding Dong, Alarm Tone
Zone Type
This option is used to program a zone type for the device.
Default: Follower
Valid
Instant, Interior, Follower,Interior Stay/Away, Delay Stay/Away, 24
range:
Hour Supervisory Buzzer, 24 Hour Non-Alarm
Device Label
This option is used to program a custom label for the wire-
less device.
Default:
Zone ZZZ
Valid range:
32 character ASCII
Section 4: Programming Options
Enabled
1-4
- 26 -
Zone Attribute
This section is used to customize zone behavior for the
device. The table below specifies the status of each attribute
for this device.
See "Available Zone Attributes" on page 32 for attribute
definitions.
Door Chime
Alarm Report
Burglary Verified
Transmission Delay
Bell Audible
Bell Steady
Bypass Enable
Force Arm
Swinger Shutdown
Two Way Audio
Talk Listen
Supervision
This option is used to enable/disable wireless supervision of
the device. Supervision monitors the presence of the wire-
less device on the alarm system.
Default:
Enabled
Valid range:
Enabled/Disabled
Alarm LED
This option is used to enable/disable the device's onboard
LED. When enabled, the LED activates when an alarm
occurs.
Default:
Enabled
Valid range:
Enabled/Disabled
24 Hour PIR
This option is used to define if motion alarms are always
enabled or only enabled at night.
Default:
Enabled
Valid range:
Enabled/Disabled
High Traffic Shutdown
Activating this feature helps conserve battery power when
the system is disarmed by configuring a reporting timer.
When motion is detected, the device transmits an alarm to
the receiver and does not report any further events until the
timer expires. Any motion detected during the configured
period is reported once the timer expires. No Delay causes
the device to report an alarm each time the detector is
tripped.
Default: Not Active
Valid
Not Active, No Delay, 5 Second Delay, 15 Second Delay, 30 Second
range:
Delay, 1 Minute Delay, 5 Minute Delay, 10 Minute Delay, 20 Minute
Delay, 60 Minute Delay
Disabled
Enabled
Enabled
Enabled
Enabled (read-only)
Enabled (read-only)
Enabled (read-only)
Disabled (read-only)
Enabled (read-only)
Enabled (read-only)
Enabled (read-only)