LED
Indicator
Remote Con-
ON Steady [Green] Link to remote server is active
ON Flash
nection Status
[Red]
OFF
Flashing
[Amber]
Note: During a system test, All LEDs flash.
Reset Button
Pressing and holding the Reset button, located under the battery cover (see figure 3-3), for a minimum of 10 seconds
defaults the interactive app to factory settings. The iotega beeps once to confirm successful reset.
Pressing and holding the Reset button for a minimum of 20 seconds resets the panels network configuration to factory
defaults. The iotega beeps twice to confirm successful reset.
Note: The system must be disarmed with no alarms in memory in order for the Reset button to function as described above.
Tamper Switch
The panel includes a tamper switch under the back battery cover. If the battery cover is removed while the system is dis-
armed, the tamper condition must be cleared before arming is permitted. If the battery cover is removed while the system is
armed, the bell sounds, a system tamper is logged and communicated to the central monitoring station, and a system tem-
per trouble is displayed in the Trouble menu.
Low Power Operation
In the event of an AC power outage, all Wi-Fi and home automation functions are discontinued. The panel uses battery
power to communicate alarms or critical conditions.

2.3 Enrolling Wireless PowerG Security Devices

Device enrollment and configuration is done using the installer portal.
To enroll wireless devices, navigate to Equipment > Sensors > Add a Sensor to put the panel into Add mode. Select Auto-
Learn or Remote Add.
Auto-Learn mode
1. Power up the sensor or device and trigger it according to the instructions in the device manual. Enrolled devices are
displayed on the Mobile Tech page in the Added Devices section.
2. Once all devices are added, choose Exit.
3. Edit the device name, group, and partition as needed.
4. Click Save to finish.
Add Sensor and Peripheral Devices (Remote Add)
1. Enter the device ID, zone definition, partition, name, and ESN into the appropriate fields.
2. Click Add Sensor to finish.
The device may need to be tampered when in range of the panel in order to start functioning.
The wireless devices in the table below each have a dedicated Enroll button, located on the circuit board inside the plastic
casing. A Phillips screw must be removed on most devices to gain access. Refer to the installation instructions provided
with the device for more information.
Section 2: Installation
Description
Link to remote server is active but has failed to communicate
Link to remote server is not active or
the panel has not been activated with Alarm.com
System Test ( AC, Ready, Trouble, Arm LED's, WiFi Trouble, Cellular Trouble &
System Remote Status flashing at same time)
Note: If the Remote Connection status LED flashes red, the panel may be having
difficulty connecting to the remote server. Restarting the panel may remedy the
issue. If the problem persists, contact technical support