1.4

SHELF POSITION

The fire may be fitted below a combustible shelf providing there is a minimum distance of 200mm
above the top of the fire and the shelf does not project more than 150mm. If the shelf overhangs
more than 150mm the distance between the fire and the shelf must be increased by 15mm for
every 25mm of additional overhang over 150mm.
1.5

HEARTHS

This appliance does not require the fitting of a hearth, but we do recommend that a hearth of
minimum width 760mm and minimum projection forwards of 125mm is used. This recommended
hearth can be manufactured from combustible or non-combustible material.