1.1
INSTALLATION CONDITIONS
It is the law that all gas appliances are installed only by a GAS SAFE Registered Installer, in
accordance with these installation instructions and the Gas Safety (Installation and Use)
Regulations 1998 as amended. Failure to install appliances correctly could lead to prosecution. It
is in your own interest and that of safety to comply with the law.
The installation must also be in accordance with all relevant parts of the Local and National
Building Regulations where appropriate, the Building Regulations (Scotland Consolidation) issued
by the Scottish Development Department, and all applicable requirements of the following British
Standard Code of Practice.
1. B.S. 5871 Part 1
2. B.S. 6891
3. B.S. 5440 Parts 1 & 2
1.2

FIREPLACE / SURROUND SUITABILITY

The fire is suitable for fitting to non-combustible fireplace surrounds and proprietary fireplace
surrounds with a temperature rating of at least 150
If a heating appliance is fitted directly against a wall without the use of a fire surround or
fireplace all combustible material must be removed from behind the trim. Soft wall
coverings such as blown vinyl, wallpaper etc. could be affected by the rising hot air and
scorching and/or discoloration may result. Due consideration should be made to this when
installing or decorating.
Installation of Gas Fires
Installation of Gas Pipework
Installation of Flues and Ventilation
o
c.
5