Lighting The Appliance - Flavel Atlanta FBFR MN Series Installation And Maintenance Instructions Manual

Radiant balanced flue gas fire
Table of Contents

Advertisement

2.11 LIGHTING THE APPLIANCE

a)
Turn on the gas restrictor at the inlet fitting.
b)
Depress the control knob and turn anti-clockwise to the position marked pilot. Hold in the
control knob for a few seconds to purge the pipe work.
c)
Continue to hold-in the control knob and press the igniter button. If the burner does not
light, continue to press the igniter button until ignition occurs. Continue to hold the control
knob for 5-10 seconds to allow thermocouple to heat up, if the pilot goes out when the
control knob is released, repeat the lighting sequence.
d)
Turn the control knob in the anti-clockwise direction to the high position and the main burner
will light.
e)
Turn the control knob clockwise to the low position and the gas input will be reduced to the
minimum setting.
f)
Slightly depress the control knob and turn to the pilot position, the main burner will go out
but the pilot will remain lit.
g)
Slightly depress the control knob and turn to the off position, the pilot is now extinguished.
h)
Finally fit the fascia
Finally, hand the Installation and Maintenance Instructions and the Users Instructions over to the
customer and explain the operation of the fire
NOTE: THIS APPLIANCE IS DESIGNED TO WORK SAFELY AND EFFECTIVELY
DURING ADVERSE WEATHER CONDITIONS. HOWEVER, DURING SUCH TIMES,
FLAME DISTURBANCE MAY BE NOTICED. THIS IS NORMAL AND DOES NOT
EFFECT OR IMPAIRE THE SAFETY OF THE APPLIANCE.
WHEN TURNING THE FIRE "OFF" PLEASE ENSURE THAT THE
CONTROLVALVE IS TURNED TO THE "OFF" POSITION AND THE PILOT
FLAME IS EXTINGUISHED. DO NOT LEAVE THE PILOT FLAME ONLY
LIT.