3. REPLACING THE IMPORTANT PARTS

3.3.6 Replacing the Stepping Motor

1. Refer to Section 3.3.5 to remove the mid cover.
2. Cut the cable tie which locates the cable of the stepping motor.
Stepping Motor
3. Use a Phillips screwdriver to remove the 3 screws and then take off the stepping motor.
Screw
4. Replace the stepping motor with a new one and then reassemble it in the reverse order of removal.
5. After replacing, perform a diagnostic test print or print a sample label to make sure the printer is
performing correctly regarding the following points.
 Printing is performed correctly.
 No noise is generated during the print operation.
Cable Tie
3-35