Extended functions
Technology Controller function module
Table 4-1
Key dancer control parameters:
Parameters
p1055
n_setp1 to RFG
p2200
BI: Technology controller enable
p2253
CI: Technology controller setpoint 1
p2263
Technology controller type
p2264
CI: Technology controller actual value
(X
)
ACT
p2280
Technology controller p gain
p2285
Technology controller integral action
time
4.1.5

Commissioning

The technology controller is activated when you are working through the commis-
sioning Wizard. Parameter r0108.16 indicates whether the function module has
been activated.
4-166
Name
p1055 = r2294 Tec_ctrl output_sig [FD 3080]
p2200 = 1 Technology controller enabled
p2253 = r2224 Fixed setpoint active [FD 7950]
p2263 = 1 D component in fault signal [FD 7958]
p2264 = r4055 [1] Analog input AI1 of TB30
p2280 Determine by optimization
p2285 Determine by optimization
Example
© Siemens AG, 2005. All rights reserved