Operating Modes
Vector V/f control (r0108.2 = 0)
Description of Vdc_max control
V
controller active
dc
Fig. 3-46
The switch-in level for Vdc_max control (r1282) is calculated as follows:
S Automatic detection of ON level deactivated (p1294 = 0)
r1282 = 1.15 * p0210 (device supply voltage)
S Automatic detection of ON level activated (p1294 = 1)
r1282 = Vdc_max -- 50 V (Vdc_max: overvoltage threshold of the Motor
Module)
Function diagram for Vdc controller (see List Manual)
S 6320
3-152
[V]
U
DC link
1
0
|n|
Switching Vdc_max control on/off
Vdc_max controller and Vdc_min controller
Switch- -on level
--{}--n
act
--{}--n
setp
© Siemens AG, 2005. All rights reserved