Operating Modes
Servo control
Function diagram overview (see List Manual)
S 5020
Parameterization
The "speed setpoint filter" parameter screen is selected via the following icon in the
toolbar of the STARTER commissioning tool:
Fig. 3-3
3.1.3

Speed controller adaptation

Description
Two adaptation methods are available, namely free Kp_n adaptation and speed-
dependent Kp_n/Tn_n adaptation.
Free Kp_n adaptation is also active in "operation without encoder" mode and is
used in "operation with encoder" mode as an additional factor for speed-dependent
Kp_n adaptation.
Speed-dependent Kp_n/Tn_n adaptation is only active in "operation with encoder"
mode and also affects the Tn_n value.
Adaptation signal 1
p1455[C]
referred to p200x or p205x
Adaptation signal 2
p1466[C]
Speed- -dependent Kp_n adaptation
Speed- -dependent Tn_n adaptation
Fig. 3-4
3-66
Speed setpoint filter and speed pre-control
STARTER icon for "speed setpoint filter"
p1459[D]
x
(0)
1458[D]
p1456[D]
(1)
Free Kp_n adaptation
y
x
p1457[D]
© Siemens AG, 2005. All rights reserved
SINAMICS S120 Function Manual, 06/05 Edition
To speed controller
without encoder
To speed controller
with encoder