Siemens SINAMICS S120 Function Manual page 225

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Scaling for object A_Inf
Table 5-7
Scaling for object A_Inf
Size
Reference frequency
Reference voltage
Reference current
Reference power
Reference control factor
Reference temperature
Reference electrical angle
Scaling for object B_Inf
Table 5-8
Scaling for object B_Inf
Size
Reference frequency
Reference voltage
Reference current
Reference power
Reference temperature
Reference electrical angle
© Siemens AG, 2005. All rights reserved
SINAMICS S120 Function Manual, 06/05 Edition
Basic information about the drive system
BICO technology: interconnecting signals
Scaling parameter
100 % = p2000
100 % = p2001
100 % = p2002
100 % = r2004
100 % = Maximum output voltage
without overload
100 % = 100°C
100 % = 90°
Scaling parameter
100 % = p2000
100 % = p2001
100 % = p2002
100 % = r2004
100 % = 100°C
100 % = 90°
Default for initial
commissioning
p2000 = p0211
p2001 = r0206/r0207
p2002 = p0207
r2004 = p0206
--
--
--
Default for initial
commissioning
p2000 = 50
p2001 = r0206/r0207
p2002 = p0207
r2004 = p0206
--
--
J
5-225

Advertisement

Table of Contents
loading

Table of Contents