Setpoint Parameters; Configuration Parameters - Riello NexPolar Series Installation And Technical Service Instructions

Table of Contents

Advertisement

OVERVIEW OF THE PARAMETERS

Setpoint parameters

Par.
Jbus
Code
401
0191H
hwoccstp
402
0192H
hwunooff
403
0193H
hwecooff
404
0194H
405
0195H
leg_stp
406
0196H
dhw_stp
407
0197H
cwoccstp
408
0198H
cwunooff
409
0199H
cwecooff
410
019A
hw_hyst
411
019B
cw_hyst
412
019C
hcurvoff
413
019D
ccurvoff
421
01A5
htoccstp
422
01A6
htunooff
423
01A7
htecooff
424
01A8
cloccstp
425
01A9
clunooff
426
01AA
clecooff
427
01AB
freezstp
428
01AC
deltastp
429
01AD
iat_fact

Configuration parameters

Par.
Jbus
Mnemonic
501
01F5
sfsw_typ
502
01F6
cust_di5
503
01F7
cust_di6
504
01F8
cust_di7
505
01F9
cust_di8
description
Home heating setpoint (water)
Sleep heating offset (water)
Away heating offset (water)
DHW Anti-legionella setpoint
DHW setpoint
Home cooling setpoint (water)
Sleep cooling offset (water)
Away cooling offset (water)
Heating hysteresis (water)
Cooling hysteresis (water)
Heating curve maximum setpoint
offset
Cooling curve minimum setpoint
offset
Home heating setpoint (air)
Sleep heating offset (air)
Away heating offset (air)
Home cooling setpoint (air)
Sleep cooling offset (air)
Away cooling offset (air)
Home freeze protection setpoint
Air delta setpoint
IAT reset factor
Description
SAFETY SWITCH
1 = the unit stops when the
contact is open
2 = floor system safety in heating
mode (heating disabled with
open contact)
3 = floor system safety in cooling
mode (cooling disabled with
open contact)
0 = not used
1 = Frequency reduction (night
mode)
2 = expensive electric power,
heating element stop (off-
peak)
3 = machine stop for renewable
energy use (loadshed)
4 = machine stop in DHW heating
mode for solar energy use
5 = boiler thermostat DHW
request
6 = absolute priority to DHW
production
7 = anti-legionella cycle
activation
8 = switching to summer mode
9 = not used
10 = not used
11,12,13 and 14 = external pulse
energy meter (1kw/pulse;
0.5kw; 0.2kw; 0.1kw)
15 = not used
range
default
20,0 - 60,0
45
=-10 - 0
0
=-10 - 0
-5.0
N.A.
50,0 - 60,0
60
30,0 - 60,0
50
5,0 - 18,0
12
0,0 - 10,0
0
0,0 - 10,0
5
0,5 - 2,0
0
0,5 - 2,0
0
=-5 - 5
0
=-5 - 5
0
12,0 - 34,0
19
=-10 - 0
-2
=-10 - 0
-4
20,0 - 38,0
26
0,0 - 10,0
2
0,0 - 10,0
4
6,0 - 12,0
6
0,2 - 1,0
0
0,0 - 2,0
0
42644,00
range
Default
1 – 3
1
0 – 15
1
0 – 15
0
0 – 15
0
0 – 15
0
66
Units
Control panel
CCN
1/10°C
RW
RW
1/10 K
RW
RW
1/10 K
RW
RW
1/10°C
RW
RW
1/10°C
RW
RW
1/10°C
RW
RW
1/10 K
RW
RW
1/10 K
RW
RW
1/10 K
RW
RW
1/10 K
RW
RW
1/10 K
RW
RW
1/10 K
RW
RW
1/10°C
RW
RW
1/10 K
RW
RW
1/10 K
RW
RW
1/10°C
RW
RW
1/10 K
RW
RW
1/10 K
RW
RW
1/10°C
RW
RW
1/10 K
RW
RW
RW
RW
Units
Control panel
CCN
-
RW
RW
-
RW
RW
-
RW
RW
-
RW
RW
-
RW
RW
Table
WAT_STP
WAT_STP
WAT_STP
WAT_STP
WAT_STP
WAT_STP
WAT_STP
WAT_STP
WAT_STP
WAT_STP
WAT_STP
WAT_STP
AIR_STP
AIR_STP
AIR_STP
AIR_STP
AIR_STP
AIR_STP
AIR_STP
AIR_STP
AIR_STP
Table
GEN_CONF
GEN_CONF
GEN_CONF
GEN_CONF
GEN_CONF