Details For Ac Mating Connector; Procedure For Creating 200-240 Vac Cable - Omron Quattro 650H User Manual

Hide thumbs Also See for Quattro 650H:
Table of Contents

Advertisement

Callout
A
User-Supplied AC Power Cable
E
Earth Ground

Details for AC Mating Connector

The AC mating connector is supplied with each system. It is shipped in the Robot Accessory
Kit. The plug is internally labeled for the AC power connections (L, E, N).
NOTE: The AC power cable is not supplied with the system. However, it is
available in the optional Power Cable kit. See List of Cables and Parts on page
72.

Procedure for Creating 200-240 VAC Cable

1. Locate the AC mating connector shown in AC Mating Connector Details on page 89.
2. Open the connector by unscrewing the screw on the shell and removing the cover.
3. Loosen the two screws on the cable clamp. See AC Power Mating Connector on page
90.
4. Use 18 AWG wire to create the AC power cable.
Select the wire length to safely reach from the user-supplied AC power source to the
robot base.
5. Strip 18 to 24 mm insulation from each of the three wires.
6. Insert the wires into the connector through the removable bushing.
7. Connect each wire to the correct terminal screw and tighten the screw firmly.
8. Tighten the screws on the cable clamp.
9. Reinstall the cover and tighten the screw to secure the connector.
10. Prepare the opposite end of the cable for connection to the facility AC power source.
09955-000 Rev. N
Description
Table 5-8. AC Mating Connector Details
AC Connector details
Quattro User's Guide
Chapter 5: System Installation
Callout
Description
L
Line 1
N
Line 2
AC in-line power plug,
straight, female, screw ter-
minal, 10 A, 250 VAC
Qualtek P/N 709-00/00
Digi-Key P/N Q217-ND
89