Display Elements

On the back side of the MA 10, there are 4 LEDs which display the momentary operating status
LED
Colour
RDY
green
ERR
yellow
ACT
red
DEC
green
Status conditions of the LEDs
All four LEDs illuminate
• for approx. 0.5 second after connecting the operating voltage.
after accepting a 'cold start' reset (> 4 s) up until the reset button is released.
All four LEDs blink
• if the connection between the MA 10 and BCL 80 is interrupted.
RDY blinks
• during the 'Power On' function test.
RDY illuminates
• when the devices are ready.
ERR illuminates
if a hardware error is encountered after the initialisation phase or in the case of a serious soft-
ware error.
RDY and ERR blink simultaneously
when the setup program is activated. Notice: No read operations can be carried out.
RDY and ERR blink alternately
• when the 'autoConfig' function is activated by setting the corresponding DIP switch.
when a reference code is defined (Teach-In).
ACT illuminates
• while the scanner is active, i.e. when the laser is in operation.
ACT blinks
• if a warning is output during the 'autoControl' function.
DEC illuminates
• for approx. 0.5 second after successfully completing a decoding process.
48
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Meaning
Ready
Error
Scanner active
Decoding successful