Installation and Operating Instructions | idOil-D30
2
Sensor connectors
46
47
48
49
50
51
The sensor connection is a polarity-free digital bus, which means
that it does not matter which sensor terminal the wires are
connected to.
3
Relay outputs
RELAY 1
19
20
21
RELAY 2
22
23
24
The maximum values presented in the technical specifications must
be taken into account.
4
Cable connector:
LCJ1-1 for a single sensor
LCJ1-1 for two sensors
LCJ1-3 for three sensors
5
Sensors
6
Extension cable, e.g. protected, twisted-pair 2 x 0.5 mm
Ohm.
Extra wires and shield must be cut and isolated carefully.
= sensor 1, connection 1
= sensor 1, connection 2
= sensor 2, connection 1
= sensor 2, connection 2
= sensor 3, connection 1
= sensor 3, connection 2
= Relay common contact
= Contact that opens in an alarm situation
= Contact that closes in an alarm situation
= Relay common contact
= Contact that opens in an alarm situation
= Contact that closes in an alarm situation
17/51
2
, maximum resistance 68
DOC001602-EN-4