Chapter 4 - Operation
CRC %: Sets up a threshold for the Cyclic Redundancy Check percentage
SNR: Sets up a threshold for the Signal-to-Noise Ratio.
Average Modulation: Sets up a threshold for the average modulation.
4.2.3.14.2.1.2Threshold Mode
This option defines how the threshold parameter (see
page
74) relates to the threshold target value (see
The available operators are:
Equal or lower than: The threshold parameter must be lower than or equal to
the threshold target value for the LED to light up.
Equal or higher than: The threshold parameter must be higher than or equal
to the threshold target value for the LED to light up.
Equal to: The threshold parameter must be equal to the threshold target value
for the LED to light up.
4.2.3.14.2.1.3Threshold Target
This option defines the threshold target value. Depending on the threshold type,
the following value ranges apply:
4.2.3.14.2.2 Show LED stats
This option displays all the threshold settings that were applied for each LED in
the SNR bar.
4.2.4

Basic Configuration Menu

The Basic Configuration menu includes all parameters required for the initial
installation and operation of the unit. After the unit is properly installed and
BreezeNET B

Table 4-4: Threshold Target Value Ranges

Threshold Value
RSSI
CRC %
SNR
Average Modulation
75
"Threshold Type" on
"Threshold Target" on page
Value Range
-108...0
0...100
0...80
1...8
Menus and Parameters
75).
System Manual