NOTE 2 (FCC 5.3 GHZ, 40 MHz Bandwidth):
For full compliance with FCC regulations, the following requirements should be
followed in units using a 40 MHz bandwidth:
In units with HW Revision B, Frequency channels 5270 and 5280 MHz should
1
not be used.
In units with HW rev C, if you wish to include frequency channel 5290 MHz in
2
the set of frequencies to be used, then the Transmit Power parameter in the
BU, and the Maximum Tx Power parameter in the RB, should not be set to a
value above "25-Antenna Gain". If there is a need to use a higher value for
these parameters, this frequency should not be used.
If you wish to include frequency channel 5310 MHz in the set of frequencies to
be used, then the Transmit Power parameter in the BU, and the Maximum Tx
Power parameter in the RB, should not be set to a value above "29-Antenna
Gain". If there is a need to use a higher value for these parameters, this
frequency should not be used.
NOTE 3 (FCC 5.3 GHZ, 10 MHz Bandwidth):
For full compliance with FCC regulation of units with HW rev C using a 10 MHz
bandwidth, if you wish to include frequency channel 5265 MHz in the set of
frequencies to be used, then the Transmit Power parameter in the BU, and the
Maximum Tx Power parameter in the RB, should not be set to a value above
"25-Antenna Gain". If there is a need to use a higher value for these parameters,
this frequency should not be used.