C U S T O M A P P L I C AT I O N E D I T O R M A N U A L
Function block reference
Analogue Command Acyclic 0
The function bocks "Analog Command Acyclic 0" provide access to the four analog words acyclically sent via fieldbus (e.g.
PROFIBUS) to the UMC. Acyclic commands are usually sent from a service tool. The command words can be sent to Slot 4/
Index 55 word 0-3. The total data block length is 8 bytes (4x2 bytes).
Function Block
Inputs
Outputs (from top to bottom)
Parameters
LCD Panel Command
This function block provides access to the commands given from the LCD panel.
Function Block
Inputs
Outputs (from top to bottom)
Parameters
Signal Name
-
Out 0 (W): First word from bus.
Out 1 (W): Second word from bus.
Out 2 (W): Third word from bus.
Out 3 (W): Forth word from bus.
-
Signal Name
-
FRev: Fast reverse start command
Rev: Reverse start command
Stop: Stop command
For: Forward start command
FFor: Fast forward start command
Fault Reset: Fault reset command
-
Data Type
-
Word
Word
Word
Word
Data Type
-
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean