C U S T O M A P P L I C AT I O N E D I T O R M A N U A L
—
Function block reference
—
Analogue Command Acyclic 0
The function bocks "Analog Command Acyclic 0" provide access to the four analog words acyclically sent via fieldbus (e.g.
PROFIBUS) to the UMC. Acyclic commands are usually sent from a service tool. The command words can be sent to Slot 4/
Index 55 word 0-3. The total data block length is 8 bytes (4x2 bytes).
Function Block
Inputs
Outputs (from top to bottom)
Parameters
—
LCD Panel Command
This function block provides access to the commands given from the LCD panel.
Function Block
Inputs
Outputs (from top to bottom)
Parameters
Signal Name
-
Out 0 (W): First word from bus.
Out 1 (W): Second word from bus.
Out 2 (W): Third word from bus.
Out 3 (W): Forth word from bus.
-
Signal Name
-
FRev: Fast reverse start command
Rev: Reverse start command
Stop: Stop command
For: Forward start command
FFor: Fast forward start command
Fault Reset: Fault reset command
-
Data Type
-
Word
Word
Word
Word
Data Type
-
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean