SolarEdge SE3000H-US Installation Manual page 80

Single phase inverter with hd-wave technology
Hide thumbs Also See for SE3000H-US:
Table of Contents

Advertisement

Technical Specifications - Single Phase Inverters with HD-Wave Technology (North America)
Revenue Grade Data, ANSI
C12.20
Rapid Shutdown - NEC 2014 and
2017 690.12
STANDARD COMPLIANCE
Safety
Grid Connection Standards 
Emissions
RoHS
INSTALLATION SPECIFICATIONS
AC output conduit size / AWG
range
DC input conduit size / # of strings
/ AWG range
Dimensions with Safety Switch
(HxWxD) 
Weight with Safety Switch
Noise
Cooling
Operating Temperature Range
Protection Rating
1 Revenue grade inverter P/N: SExxxxH-US000NNC2
2 For power de-rating information refer to:
3 -40 version P/N: SExxxxH-US000NNU4
Single Phase Inverter with HD-Wave Technology Specifications (North America) MAN-01-00308-1.3
SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US
Automatic Rapid Shutdown upon AC Grid Disconnect
UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07
3/4" minimum / 14 - 6 AWG
3/4" minimum / 1-2 strings / 14-6 AWG
17.7 x 14.6 x 6.8 / 450 x 370 x 174
22 / 10
25.1 / 11.4
< 25
Natural Convection 
https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf
1
Optional
IEEE1547, Rule 21, Rule14 (HI)
FCC part15 class B
Yes
26.2 / 11.9
Natural convection and internal fan (user replaceable)
2
-13 to +140 / -25 to +60
(-40°F / -40°C option)
IP65/ NEMA 3R (Inverter with Safety Switch)
3/4" minimum / 14-4 AWG
3/4" minimum / 1-3 strings /
14-6 AWG
21.3 x 14.6 x 7.3 / 540 x 370 x 185
38.8 / 17.6
< 50
3
Unit
in/mm
lb / kg
dBA
°F/ °C
80