Error Codes
Code
CPU
v3.18xx
CPU v3.19xx
and
and above
below
44
3xB
45
3x2
48
3xF
176
3x6A 
178
3x6D
185
3x6E
193
3x6A
169
18xA9
166-168, 
18xA6-A8 , 
170
18xAA 
171
18xAB
12
18xC
13
18xD
55
18x37
64
Single Phase Inverter with HD-Wave Technology Installation MAN-01-00306-1.1
Error
Message
No Country 
Select the country as described in Country and Grid on page 41
Selected 
Inv. Comm. 
No communication with the digital board. Contact SolarEdge 
Error 
support.
SW Error 
Contact SolarEdge support.
For info 
contact your 
 Inverter remotely locked. Contact your installer.
installer
Check:
Internal RGM 
 
 The wiring of the meter CTs
l
Error 
 
Connections to the inverter communication board.
l
Refer to the meter troubleshooting in  
Meter Comm. 
Error 
http://www.solaredge.com/files/pdfs/solared
ge-meter-installation-guide-na.pdf
OFF/ON to 
Turn the ON/OFF switch to ON to initiate production.
Reconnect 
 
RCD Sensor Error. Contact SolarEdge support.
HW error
Contact SolarEdge support.
Over voltage 
Over voltage in DC input of the inverter. Check the strings' 
Vin
voltage.
Refer to 
ARC_
DETECTED
https://www.solaredge.com/sites/default/fil
es/arc_fault_detection_application_note_na.pdf.
ARC_PWR_
 
DETECT
 
 
AC voltage too high
 
Verify that the inverter is set to the correct country.
o
V-Line Max
 
 Turn OFF the inverters in the site and verify AC grid 
o
voltage. 
Troubleshooting