String voltage is higher than number of optimizers
WARNING!
If the measured voltage is too high, the installation 
may not have a safe low voltage. PROCEED WITH 
CARE!   A  deviation of ±1% per string is reasonable. 
Si la tension mesuree est trop haute, la tension basse
de securite pourrait manquer dans l'installation.
REDOUBLEZ DE PRECAUTION. Une deviation de
±1% par string est raisonnable.
Single Phase Inverter with HD-Wave Technology Installation MAN-01-00306-1.1
Problem
Appendix A: Errors and Troubleshooting
Possible cause and
troubleshooting
Extra power optimizer(s) connected in the 
string (not applicable to smart modules). 
Check if an extra power optimizer is connected 
in the string. If not – proceed to next solution.
A module is connected directly to the string, 
without a power optimizer (not applicable to 
smart modules). 
Verify that only power optimizers are 
connected in the string and that no module 
outputs are connected without a power 
optimizer.   I f the problem persists, proceed to 
the next step.
Power optimizer(s) malfunction.
 
Disconnect the wires connecting the power 
o
optimizers in the string.
 
Measure the output voltage of each power 
o
optimizer to locate the power optimizer that 
does not output 1V safety voltage. If a 
malfunctioning power optimizeris located, 
check its connections, polarity, module, 
and voltage.
 
Contact SolarEdge Support. Do not 
o
continue before finding the problem and 
replacing the malfunctioning power 
optimizer. If a malfunction cannot be 
bypassed or resolved, skip the 
malfunctioning power optimizer, thus 
connecting a shorter string. 