6.3.5

Line splitter

For the field installation of the inductive switches, Linear Axis of the AXC, AXDL and AXLT series can be equipped with line line splitters.
Depending on the number of required switches, Y line splitter for two or sensor boxes for four switches are available.
Line splitters have to be specified as special options of the Linear Axis and will be delivered with fully wired limit switches. For the
connection to the signal processing controler, fixed cables, connectors as well as fieldbus and IO-Link are available.
6.3.6
Technical data
The technical data of the available switches and position measuring systems are contained in the Tables 6.33 to 6.36.
Table 6.33 __ Mechanical safety limit switches
Switch
Life time
M1
30 x 10
6
switching operations
M2
30 x 10
6
switching operations
M3
10 x 10
6
switching operations
M4
30 x 10
6
switching operations
M5
30 x 10
6
switching operations
Switching segment: Snap-action switch (force disconnection) each case 1 x opener and 1 x closer
Table 6.34 __ Inductive proximity switches
Switch
Connection voltage
AXC-Initiator
10...30 V DC
I1
10...30 V DC
I2
12...30 V DC
The magentic field switch detects the magnetic field of the in the slider integrated magnet. Due to the contactless position detection
is the function of the magnetic field switches reliable and without wear.
Table 6.35 __ AXF – Magentic field switch
Switch
Connection voltage
AXF Magentic field switch
10...30 V DC
The magnet encoded position measuring system is a contactless incremental measuring system, consisting of sensor head and
magnetic tape, which is available in several versions. All functions are realized via magnetic sensing.
Table 6.36 __ Magnetic encoded position measuring system
Reference point
Switch
Output signal
signal
Sinusoidal analog
T1
without
signals Sin/Cos
Sinusoidal analog
1 Reference point
T2
signals Sin/Cos
signal
Distance-coded
Sinusoidal analog
T3
reference point
signals Sin/Cos
signals
fix periodic
Sinusoidal analog
T4
reference point
signals Sin/Cos
signals
Housing material
Plastic
Plastic
Screwed connection 4 x M3,5
Metal
Plastic
Plastic
Max. load current
100 mA
≤ 2% of the reacting distance
100 mA
≤ 10% of the reacting distance
100 mA
≤ 5% of the reacting distance
Rated operational current
200 mA
Total
Output
Operating
Maximum
system
voltage
voltage
velocity
accuracy
(A/B/Z)
5 V ± 5% ± 10µm
1 Vss
5 m/s
5 V ± 5% ± 10µm
1 Vss
5 m/s
5 V ± 5% ± 10µm
1 Vss
5 m/s
5 V ± 5% ± 10µm
1 Vss
5 m/s
202
Cable gland
Conductor cross-section
M20 x 1,5
0,5...2,5 mm²
0,5...1,5 mm²
Screwed connection
max. 1,5 mm²
M20 x 1,5
0,5...2,5 mm²
M20 x 1,5
0,5...2,5 mm²
Switching accuracy
Cable length
Rated switching field intensity
1,2 kA/m
Protection
Sensor head
class
IP67
IP67
IP67
IP67
Protection class
IP67
IP30
IP67
IP67
IP67
Protection class
10 m
IP67
5 m
IP67
2 m
IP67
Cable length
Protection class
5 m
IP67
Magnetic tape
with alternating north and south poles
with one reference point signal
with reference point signals according
mathematical algorithm
with several reference point signals
at the same distance