Maximum Static Load Capacity - NTN-SNR LINEAR AXIS AXC Series Manual

Linear motion
Table of Contents

Advertisement

5.4.2.3

Maximum static load capacity

Type
AXDL110S
AXDL110T
AXDL160S
AXDL160T
AXDL240S
AXDL240T
5.4.2.4
Dynamic load capacity
The dynamic load capacities of the guiding systems are based on a nominal life time of 25 000 km.
Type
AXDL110S
AXDL110T
AXDL160S
AXDL160T
AXDL240S
AXDL240T
Load
Guiding system
F
y
D
7 900
D
32 000
D
42 500
E
51 000
Load
Guiding system
F
y
D
2 900
D
11 500
D
16 000
E
18 000
98
[N]
F
M
z
x
7 900
275
32 000
1 600
42 500
3 550
51 000
4 300
[N]
F
M
z
x
2 900
100
11 500
575
16 000
1 350
18 000
1 500
Load moment
[Nm]
M
M
y
z
375
375
2 200
2 200
3 950
3 950
8 750
8 750
Load moment
[Nm]
M
M
y
z
140
140
800
800
1 500
1 500
3 100
3 100