Pepperl+Fuchs VBG-ENXK20-DMD-EV Manual page 49

As-i 3.0 ethernet/ip+ modbus tcp gateway
Hide thumbs Also See for VBG-ENXK20-DMD-EV:
Table of Contents

Advertisement

AS-i 3.0 EtherNet/IP+Modbus TCP Gateway
EtherNet/IP interface
CA (configuration_active): The configuration-mode is active
AAv (Auto_Address_Available): Automatic programming is possible
AAs (Auto_Address_Assign): Automatic programming is allowed
Cok (config_ok): Configuration error:
Hi-flags (8-bit)
2
1
0
2
2
2
AAe
OL
DX
AAe: Auto_Address_Enable
OL: Off-line
DX: Data_Exchange_Active
Operational mode (8-bit):
1: configuration mode
0: protected mode
LDS, LAS, LPS, LPF (64-bit)
Byte
7
6
2
2
0
7A
6A
...
...
7
31B
30B
LDS: list of detected slaves
LAS: list of activated slaves
LPS: list of activated slaves
LPF: list of peripheral faults
0: Auto-address is possible
1: Auto-address is not possible
S0 (LDS.0): There is an AS-i slave with address '0'
0: no error
1: error
5
4
3
2
2
2
5A
4A
3A
29B
28B
27B
2
1
0
2
2
2
2A
1A
0A
26B
25B
24B
Tab. 10-14.
Tab. 10-15.
49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vbg-enxk20-dmdVbg-enxk20-d

Table of Contents