2 Overview
2-5-3

Operation Mode

The Master Unit has the following operation modes.

Operation mode

RUN
TEST
ID
The operation mode can be switched by the mode settings switch of Master Unit.
2-5-4
Assignment Relationship Between Slave Button and Outputs of
Master Unit
All assignments can be made between 8 Slave buttons and 8 outputs of the Master Unit.
Duplicate assignment is possible. A total of 8 × 8 = 64 patterns can be assigned.
• Multiple Slave buttons can be assigned to the same output.
• The same Slave button can be assigned to multiple outputs of the Master Unit.
• The above combinations are also possible.
Examples of various assignments are shown below.
For additional reference information, the ladder diagram circuit equivalent to the OR logic is shown on
the right side.
Multiple Slave Buttons Are Assigned to the Same Output
Master
Unit
Slave
buttons
(a)
In the above example, when operating either of Slave button (a), (b), or (c) once, the No.2 output will
be outputted in one shot.
2 - 18
Mode name
Communications
Receives data from the Slave button and performs transistor output.
mode
(During normal operation)
Test mode
Even if data is received from the Slave button, transistor output is not
performed. (During testing)
ID mode
Register or delete the Slave button ID. (When setting)
Output No. 2
Example: Three Slave button (a), (b),
and (c) are assigned to the
same output No. 2.
(b)
(c)
Function
Input
Output No. 2
(a)
(b)
(c)
Wireless Pushbutton Switch User's Manual (A265)