Model Number Structure

■ Model Number Legend
Switches
D4JL-@@@@-@@-@@
1 2 3 4
5 6
1. Conduit Size
1: Pg13.5
2: G1/2
3: 1/2-14NPT (See note 2.)
4: M20
2. Built-in Switch
N: 2NC/1NO slow-action contacts plus 2NC/1NO slow-action
contacts
P: 2NC/1NO slow-action contacts plus 3NC slow-action contacts
Q: 3NC slow-action contacts plus 2NC/1NO slow-action contacts
R: 3NC slow-action contacts plus 3NC slow-action contacts
3. Head Material
F: Plastic
4. Door Lock and Release
A: Mechanical lock/24-VDC solenoid release
G: 24-VDC Solenoid lock/Mechanical release
5. Indicator
C: 24 VDC (green LED indicator)
D: 24 VDC (orange LED indicator)
6. Release Key Type
5: Special release key (See note 3).
6: Special release key plus rear release button (See note 3).
7: Trapped key
7. Trapped Key Type
01 to 30: 30 types (See note 4.)
Note: 1. A 24-VDC solenoid lock cannot be combined with a trapped key.
A 24-VDC solenoid lock cannot be combined with a special release key and rear release button.
2. Models with M20 conduits come with an M20 to 1/2-14NPT Adaptor.
3. Release keys are provided.
4. Thirty types of trapped keys can be manufactured. Specify the trapped key type in numerical order starting from 01 when ordering.
52
Guard Lock Safety-door Switch
7
D4JL

Operation Keys

D4JL-K@
1
1. Operation Key Type
1: Horizontal mounting
2: Vertical mounting

Advertisement