Operation Keys

Type
Horizontal mounting
Vertical mounting
Adjustable mounting
(Horizontal)
Adjustable mounting
(Horizontal/Vertical)

Specifications

Standards and EC Directives
Applicable EC Directives and Standards
• Machinery Directive
• Low Voltage Directive
• EN1088
• EN60204-1
• GS-ET-19
Approved Standards
Agency
TÜV Product
EN60947-5-1 (approved
Service
direct opening)
UL (See note 2.)
UL508, CSA C22.2 No.14
Note: 1. Consult your OMRON representative for details.
2. Approval for CSA C22.2 No. 14 is authorized by the UL
mark.
4
Model
D4DS-K1
D4DS-K2
D4DS-K3
D4DS-K5
Standard
File No.
(See note 1.)
E76675
Approved Standard Ratings
TÜV (EN60947-5-1)
Utilization
Item
category
Rated operating current (I
)
e
Rated operating voltage (U
e
Note: Use a 10-A fuse type gI or gG that conforms to IEC269 as a short-circuit
protection device. This fuse is not built into the Switch.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Rated
Carry current
voltage
120 VAC
10 A
60 A
240 VAC
30 A
Solenoid Coil Characteristics
Item
24 VDC
Rated operating
24 VDC +10%/
− 15%
voltage (100% ED)
Current consump-
Approx.
tion
200 mA
Class F (130 ° C max.)
Insulation
Indicator Characteristics
Item
Rated voltage
10 to 115 VAC/VDC
Current leakage
Approx. 1 mA
Color (LED)
Orange
Safety Sensors / Components
AC-15
DC-13
3 A
0.27 A
) 240 V
250 V
Current
Volt-amperes
Make
Break
Make
6 A
7,200 VA 720 VA
3 A
110 VAC
230 VAC
110 VAC ± 10% 230 VAC ± 10%
Approx. 50 mA Approx. 30 mA
LED
Break

Advertisement