VERSION 07/2017
OPERATING MANUAL
3
IDENTIFICATION
3.1
EXPLOSION PROTECTION IDENTIFICATION
As defined in the Directive 2014/34/EU (ATEX), the device is suitable for use in potentially
explosive areas.
Device type:
Manufacturer:
II 2G X
CE
Ex
II
2
G
X
3.2
IDENTIFICATION "X"
Ignition temperature of the coating product
Ensure that the ignition temperature of the coating product is above the maximum
surface temperature (85 °C; 185 °F).
Ambient temperature
Permissible ambient temperature: +5 °C to +40 °C; +41 °F to +104 °F.
Cleaning
If there are deposits on the surfaces, the device may form electrostatic charges. Flames or
sparks can form during discharge.
Remove deposits from the surfaces to maintain conductivity.
3.3
USE IN AREAS SUBJECT TO EXPLOSION HAZARDS
Safe handling of WAGNER spray devices
Mechanical sparks can form if the device comes into contact with metal.
In an explosive atmosphere:
Do not knock or push the device or components and tools against steel or rusty iron.
Do not drop the device or components and tools.
National regulations
Ensure that the national explosion prevention rules and regulations are observed
when setting up the device.
ORDER NUMBER DOC 2349369
Airless manual gun
Wagner International AG
CH-9450 Altstätten, Switzerland
European Communities
Symbol for explosion protection
Device class II
Category 2 (Zone 1)
Ex-atmosphere gas
Special notes (see Chapter 3.2)