4.2.1 USE PERSONAL SAFETY EQUIPMENT
Hazard due to dangerous fluids or steam!
Serious or fatal injuries due to inhalation, swallowing or contact with the skin or eyes.
When preparing or working with paint and when cleaning the device, follow the
working instructions of the manufacturer of the lacquers, solvents, and cleaning
agents being used.
Take the specified protective measures. In particular wear safety goggles, protective
clothing and gloves, as well as hand protection cream if necessary.
Use a mask or breathing apparatus if necessary.
For sufficient health and environmental safety: Operate the device in a spray booth
or on a spraying wall with the ventilation (extraction) switched on.
Wear suitable protective clothing when working with hot products.
4.2.2 SAFE HANDLING OF WAGNER SPRAY DEVICES
Hazard due to injection of lacquer or flushing agent into the skin!
The spray jet is under pressure and can cause dangerous injuries. Avoid injection of paint
or flushing agents:
Never point the spray gun at people.
Never reach into the spray jet.
Before any work on the device, in the event of work interruptions and malfunctions:
- Relieve the pressure from the spray gun and device.
- Secure the spray gun against actuation.
- Switch off the energy/compressed air supply.
- Disconnect the control unit from the mains.
- In the event of functional faults, remedy the fault as described in the
"Troubleshooting" chapter.
If needed, the liquid ejection devices must be checked by experts (e.g., WAGNER
service technician) at least every 12 months for their work-safe condition in
accordance with DGUV regulation 100-500 Chapter 2.29 and Chapter 2.36.
– For shut down devices, the examination can be suspended until the next start-
up.
Carry out the work steps as described in the "Pressure relief" chapter:
- If pressure relief is required.
- If the spraying work is interrupted or stopped.
- before the device is cleaned on the outside, checked or serviced,
- Before the spray nozzle is installed or cleaned.
In the event of skin injuries caused by lacquer or flushing agents:
Note the lacquer or flushing agent that you have been using.
Consult a doctor immediately.
Danger due to recoil forces!
Actuating the trigger can causes strong recoil forces. Thereby the user can lose his
balance and injure himself during falling.
Avoid risk of injury from recoil forces:
Ensure that you have firm footing when operating the spray gun.
ORDER NUMBER DOC 2349369