WAGNER PROTEC GM 1-530 Translation Of The Original Operating Manual page 21

Airless manual gun
Hide thumbs Also See for PROTEC GM 1-530:
Table of Contents

Advertisement

VERSION 07/2017
OPERATING MANUAL
Anti-contact guard 7/8 UNF
CAUTION
1.
Product emission from product inclusions between nozzle and valve seat!
Injury due to contact with dangerous liquids.
When loosening the anti-contact guard, always keep the spray gun pointed at
the ground.
Clean the nozzle in accordance with Chapter 7.2.4.
7.2.6 HORIZONTAL/VERTICAL SPRAYING
Nozzle holder PT-HD GM1
1. Secure the spray gun with the locking device.
2. Rotate the reversing nozzle 90° to the right, so that the nozzle is pointing transverse
to the direction of spray.
3. Turn the nozzle holder to the desired position.
Attention: always turn the nozzle holder clockwise (see illustration) so that the
threaded connection cannot become loose. After turning, check whether the nozzle
holder is tight. If not, tighten.
4. Turn the reversing nozzle back into the spray position.
Vertical spraying
Nozzle holder WAGNER Tip 7/8 UNF
1. Relieve the pressure on the spray gun and product pressure generator in
accordance with Chapter 7.2.2.
2. Secure the spray gun with the locking device.
3. Loosen the anti-contact guard by a few rotations.
4. Setting the nozzle lever:
- Nozzle horizontal – spray jet vertical
- Nozzle vertical – spray jet horizontal
5. Tightly fasten union nut.
See also WAGNER Tip (For Order No., see Chapter 1.3).
Anti-contact guard 7/8 UNF
1. Relieve the pressure on the spray gun and product pressure generator in accordance
with Chapter 7.2.2.
2. Secure the spray gun with the locking device.
3. Point the spray gun at the ground. Loosen anti-contact guard.
4. Align nozzle and tighten the anti-contact guard with a size 27 wrench (SW 27).
ORDER NUMBER DOC 2349369
Horizontal spraying
B_06763