8

CLEANING AND MAINTENANCE

8.1

CLEANING

8.1.1 CLEANING STAFF
Cleaning work should be undertaken regularly and carefully by qualified and trained staff.
They should be informed of specific hazards during their training.
The following hazards may arise during cleaning work:
- Health hazard from inhaling solvent vapors
- Use of unsuitable cleaning tools and aids
8.1.2 FLUSHING AND CLEANING THE SPRAY GUN
The spray gun and the device must be
cleaned and flushed daily. The cleaning
and flushing agents used must be
compatible with the working material.
Note:
Methylene chloride is not recommended
as an agent for flushing or cleaning the
spray gun or other system components.
Description
1
Product inlet
2
Locking device in secured
position
1. Relieve the pressure on the spray gun and product pressure generator in accordance
with Chapter 7.2.2.
2. Secure the spray gun with the locking device.
3. Connect the solvent supply.
4. Disassemble the Airless nozzle and clean it separately (see Chapter
5. Raise the pressure of the rinsing agent supply to a maximum of 4 MPa; 40 bar; 580
psi, unlock the spray gun and thoroughly rinse it.
6. Relieve the pressure on the spray gun and product pressure generator.
7. Secure the spray gun with the locking device.
8. Clean the gun body with a cleaning agent recommended by the lacquer
manufacturer. Clean the trigger locking device area.
9. Dry with a cloth or a blow gun.
ORDER NUMBER DOC 2349369
1
B_5045
2
7.2.3
and 7.2.4).