WAGNER PROTEC GM 1-530 Translation Of The Original Operating Manual page 25

Airless manual gun
Hide thumbs Also See for PROTEC GM 1-530:
Table of Contents

Advertisement

VERSION 07/2017
OPERATING MANUAL
8.2.5 REPLACING THE PRODUCT HOSE
1. Flush and clean the spray gun as described in Chapter 8.1.2.
2. Relieve the pressure on the spray gun and product pressure
generator in accordance with Chapter 7.2.2.
3. Secure the spray gun with the locking device.
Product hose
4. Place the size B wrench on the lower wrench size across flats
of the product connection and hold it in place.
5. Unscrew the product hose nut using the size A wrench.
Assembly
6. Fit product hose by hand and tighten with 2 wrenches.
Description
PROTEC GM 1-350/530
with filter NPS1/4"
8.2.6 REPLACING THE NOZZLE SEAL
Nozzle holder PT-HD GM1
1. Flush and clean the spray gun as described in
Chapter 8.1.2.
2. Ensure that the system has been relieved of
pressure and that the spray gun is secured.
3. Remove reversing nozzle (A).
4. Unscrew nozzle holder (B).
5. Carefully release saddle (C) and nozzle sealing (D)
using a screwdriver.
6. Insert a new nozzle seal (D) and saddle (C) into
the nozzle holder noting the installation position
(see illustration).
7. Screw the nozzle holder onto the spray gun and
push the reversing nozzle (A) into the opening.
The tip of the reversing nozzle must point
forward in the direction of spray.
Nozzle holder WAGNER Tip 7/8 UNF
1. Flush and clean the spray gun as described in Chapter 8.1.2.
2. Ensure that the system has been relieved of pressure and that the spray gun is
secured.
3. Replace the seal in accordance with supplement WAGNER Tip (For Order No., see
Chapter 1.3).
Anti-contact guard 7/8 UNF
1. Flush and clean the spray gun as described in Chapter 8.1.2.
ORDER NUMBER DOC 2349369
Wrench A
Wrench B
Wrench size
Wrench size
17 mm
19 mm
0.67 inch
0.75 inch
B_5048
D
B_5051
B
A
A
C
B
25