Warnings - EWM Taurus **5 Basic S Series Operating Instructions Manual

Table of Contents

Advertisement

Rectifying faults

Warnings

Category
a)
b)
58
59
60
61
62
[1]
factory setting
[2]
option
[3]
only machine series Titan
[4]
not machine series Titan
7.2
Warnings
A warning is denoted by the letter A on the machine display, or Att in case of multiple machine
displays. The possible cause of the warning is signalled by the respective warning code (see
table).
In case of multiple warnings, these are displayed in sequence.
Document machine warning and inform service personnel, if required.
Warning
1 Excess temperature
4 Shielding gas
5 Coolant flow
6 low wire
7 CAN bus failure
8 Welding circuit
10 Partial inverter
11 Excess temperature, coolant
12 Welding monitor
32 Tacho error
33 WF excess current
34 JOB unknown
35 WF excess current slave
36 Slave tacho error
36
Error
Possible cause
c)
Permanent overload of the wire
drive (slave drive)
Short circuit
Check welding circuit for short
circuit
Incompatible
A machine connected to the
machine
system is not compatible
Incompatible
A machine's software is not
software
compatible.
Welding
The actual value of a welding
monitor
parameter is outside the
specified tolerance field
System
System component not found
[3]
component
Possible cause
Shut-down due to excess temperature imminent.
[2]
Check shielding gas supply.
[3]
Flow rate (<= 0.7l/min / <= 0.18 gal./min)
Nearly no wire left on the spool.
Wire feeder not connected, automatic circuit-breaker of wire
feed motor (reset triggered machine by pressing).
The welding circuit inductance is too high for the selected
welding task.
One of several partial inverters is not supplying welding
current.
[3]
Coolant (>= 65°C / >= 149°F)
The actual value of a welding parameter is outside the
specified tolerance field.
Fault of wire feeder, permanent overload of the wire drive.
Overcurrent detection of the wire main drive.
JOB selection was not performed because the JOBnumber is
unknown.
Overload of the slave wire drive (front drive push/push system
or intermediate drive).
Fault of wire feeder, permanent overload of the slave wire
drive (front drive push/push system or intermediate drive).
Remedy
Do not place the liner in tight
radii; check wire core for
smooth movement
Check welding circuit; isolate
welding torch before
depositing
Please disconnect the
incompatible machine from
the system
Inform Service
Observe tolerance fields;
adjust welding parameters
Inform Service
[1]
[1]
099-005589-EW501
20.03.2019

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taurus **5 steel puls sTaurus **5 steel synergic s seriesTaurus 505 basic sTaurus 405 basic sTaurus 405 steel synergic sTaurus 505 steel synergic s ... Show all

Table of Contents