Error messages (power source)
A welding machine error will be signalled by an error code (see table) on the control display. In
the event of an error, the power unit shuts down.
The display of possible error numbers depends on the machine version (interfaces/functions).
Document machine warning and inform service personnel, if required.
If there are several errors in a control system, the error with the lowest error number (Err) is displayed.
If this error is corrected, the next higher error number appears. This process is repeated until all errors
have been resolved.
Categories legend (resetting the error)
a) The error message will disappear once the error has been rectified.
b) The error message can be reset by pressing a push-button
c) The error message can only be reset by switching the machine off and on again.
Category
a)
b)
3
4
5
6
7
8
34
Error
Possible cause
c)
Tacho error
Error of wire feeder
Permanent overload of the wire
drive
Excess
Power source overheated
temperature
Fan blocked, dirty or defective
Air inlet or outlet blocked
Mains
Mains voltage is too high
overvoltage
Mains
Mains voltage is too low
undervoltage
Low coolant
Flow rate too low (< = 0.7 l/min)
level
/ (< = 0.18 gal/min)
Coolant volume too low
Pump does not run
Air in the coolant circuit
Hose package not completely
filled with coolant
Operation with gas-cooled
welding torch
Failure of automatic circuit-
breaker
Shielding gas
No shielding gas
:
[1] [3]
[4]
Remedy
Check connections
(connections, pipes)
Do not place the liner in tight
radii; check wire core for
smooth movement
Allow the power source to
cool down (mains switch to
"1")
Check fan and clean or
replace
Check air inlet and outlet
Check the mains voltages and
compare with the power
source connection voltages
Check coolant flow, clean
water block, remove kinks in
hose package, adjust flow
threshold
Fill coolant
Turn the pump shaft
Vent coolant circuit
Switch machine off / on (pump
runs for 2 min)
Connect coolant feed and
coolant return (insert hose
bridge); deactivate water
block
Press to reset automatic
circuit-breaker
Check shielding gas supply