CHAPTER 7 Hot Swapping
(15) GSWBs
Redundant configuration and hot swapping are available.
If two GSWBs are mounted and redundant operation is performed by LAN
redundancy software (PRIMECLUSTER GLS), hot swapping is available.
(16) OP Panels
Redundant configuration is not adopted, but hot swapping is available.
(17) PSUs
Redundant configuration is adopted, and hot swapping is available.
(18) FAN TRAYs
Redundant configuration is adopted, and hot swapping is available.
(19) FANs
Redundant configuration is adopted, and hot swapping is available. However, since
FANs are contained in a FAN TRAY, replacement of only a single FAN is not
possible.
(20) PCI_Boxes
Hot swapping is available. Hot swapping is available for the entire PCI_Box.
A redundant configuration is also available by using mirroring software (such as
PRIMECLUSTER GDS).
(21) PCIUs
Hot swapping is available.
A redundant configuration is also available by using mirroring software (such as
PRIMECLUSTER GDS).
(22) PCI cards
Hot swapping is available. Hot swapping is available while a PCI card is inserted to a
PCI cassette.
A redundant configuration is also available by using mirroring software (such as
PRIMECLUSTER GDS).
7-8