4. Set the appropriate values, then click the
Figure 4-54 MODEM Maintenance Control Box
Parameter
TX Mute Control
Release Time
5.
Figure 4-55 Warning Dialog Box
6.
Figure 4-56 Information Dialog Box
iPASOLINK EX Advanced: O
Value
On
Off
90 [s]
180 [s]
300 [s]
60 [min]
12 [h]
dialog box appears. Click the
Warning
Information
dialog box appears. Click the
The
MODEM Maintenance Control
& M
PERATION
AINTENANCE
OK
Table 4-5 TX Mute Control
Description
Executes the forced mute.
Releases the forced mute. [default]
Provides 90 seconds before executing the auto-recovery.
Provides 180 seconds before executing the auto-recovery.
Provides 300 seconds before executing the auto-recovery.
Provides 60 minutes before executing the auto-recovery.
Provides 12 hours before executing the auto-recovery.