4.3.2 Link OAM Loopback

To operate the Link OAM Loopback, the Link OAM Mode must be enabled and be
active. Check or enable the Link OAM function referring to the Set Network and
System Provisioning manual, 8.6.4 LINK OAM Setting .
Figure 4-8 Link OAM Loopback Configuration
Procedure 4-3
1. Click the
2. In the
GGS-000548-01E
iPASOLINK EX/A
ETHERNET PORT
Maintenance
system into the Maintenance Mode. The
changes to orange.
frame on the left, expand the
MENU
submenu
Loopback Control
The
Link OAM Loopback Control
tool button on the tool bar of the
MAINT
to select
Link OAM Loopback Control
window appears.
iPASOLINK EX Advanced: Operation & Maintenance
CONTROL ITEMS
iPASOLINK EX/A
ETHERNET PORT
LOOPBACK
WebLCT