Henny Penny Evolution Elite EEG-16 Series Technical Manual page 97

Open fryer
Table of Contents

Advertisement

the modules. Verify high limit thermocouples are clean
and mounted properly to the heating elements.
Test filtration system – motor is running, oil is pumping
freely back to fry pot. No leaks and no leaks back to
32.
drain pan (drain valve, check valve not leaking). Pump
all oil back to fry pot.
Check that all six heating circuits have similar amp
33.*
draw. Electrically troubleshoot issues if any are found.
Pressure System
Remove lid cover and inspect lid components – Please
read and follow PXE-100 Lid Inspection instructions for
34.
this step.
Remove and inspect the lid gasket and check the tight-
ness of lid liner screws as per the instructions for this
step. Replace the gasket if it has not been replaced in
35.*
the last 12 months, or if the gasket is hardened, brittle,
damaged, or blackened.
Inspect Lid Handle Rollers – Please read and follow all
36.
instructions for this step.
Inspect cam slide fillers located on each side of the lid
37.
cover.
Inspect front lid latch and make adjustments as
38.
necessary.
Inspect pressure pads. Rotate if excessively worn, re-
39.
place if cracked or both sides are excessively worn.
Manually test lid pin switch. Refer to test instructions.
40.
Check error log and address recent pressure errors.
41.
General Fryer, ATO, and Filtration System
Verify all labels are in place and legible on fryer.
42.
43.
Note errors from the last week.
Test the JIB pump.
44.
85