Henny Penny Evolution Elite EEG-16 Series Technical Manual page 42

Open fryer
Table of Contents

Advertisement

5 5 . . 4 4 . . 5 5 T T - - 6 6 - - D D i i g g i i t t s s T T e e s s t t
Press the timer 1 button to view all segments of each digit across the displays.
1 1 ) )
5 5 . . 4 4 . . 6 6 T T - - 7 7 - - D D e e c c i i m m a a l l P P t t s s T T e e s s t t
Press the timer 1 button to view all decimal points across the displays.
1 1 ) )
5 5 . . 4 4 . . 7 7 T T - - 8 8 - - L L E E D D ' ' S S T T e e s s t t
Press the timer 1 button to view each LED across the control panel.
1 1 ) )
5 5 . . 4 4 . . 8 8 T T - - 1 1 7 7 - - I I n n p p u u t t s s - - H H D D F F
H = HIGH LIMIT - If "H" is present, the high limit is good. If "-" shows then the high limit
is tripped out (overheated) or disconnected.
D = DRAIN SWITCH - If "D" is present, the drain handle (when applicable) is closed. If
"-" shows then the drain is open or the switch is faulty.
F = FAN (PRESSURE SWITCH) - If "F" is present, the pressure witch is good. If "-"
shows in the display, the switch is faulty.
Press the down arrow and an underscore ("_") indicates the input is not
1 1 ) )
presently detected. A checkmark ("√" ) indicates the signal is detecting a normal
input. A blinking ("X") indicates the signal is presently detected, but is detected
as a half-wave (partially failed) input.
NOTE: The H, D, F signals above are wired in series. The first signal missing out of
this sequence l generally causes all signals to the right of it to be missing as well.
5 5 . . 4 4 . . 9 9 T T - - 1 1 8 8 - - O O u u t t p p u u t t s s
S = SAFETY GAS VALVE (if available) - Press product button 7 to open and close the
gas safety valves.
H = HEAT OUTPUTS - Press product button 9 to turn on and off the heating outputs
(ex: gas valve).
Press the right arrow and "7. OUTP" and "F-S-I-H-" show in displays.
1 1 ) )
F = FAN (PRESSURE SWITCH) - Press product button 1 or 6 to open and close
the pressure switches
S = SAFETY GAS VALVE (if available) - Press product button 2 or 7 to open
and close the gas safety valves.
I = IGNITION MODULE - Press product button 3 or 8 to open and close the
outputs on the ignition modules.
H = HEAT OUTPUTS - Press product button 4 or 9 to turn on and off the heating
outputs (ex: gas valve).
5 5 . . 4 4 . . 1 1 0 0 T T - - 2 2 0 0 - - A A I I F F B B o o a a r r d d I I n n p p u u t t s s
E = Stop button
Ex = E-Stop pressed.
P = Drain Pan
Px = drain pan is missing.
JL = JIB
Jx = JIB oil level is low.
R = RTI
Rx = RTI System NOT Detected
DT = Discard Tank
30

Hide quick links:

Advertisement

Table of Contents
loading