Henny Penny Evolution Elite EEG-16 Series Technical Manual page 60

Open fryer
Table of Contents

Advertisement

6 6 . . 1 1 0 0 J J I I B B P P u u m m p p R R e e p p l l a a c c e e m m e e n n t t
Remove electrical power supplied to the unit.
1 1 ) )
W W A A R R N N I I N N G G ! ! S S H H O O C C K K H H A A Z Z A A R R D D T T o o a a v v o o i i d d e e l l e e c c t t r r i i c c a a l l s s h h o o c c k k o o r r p p r r o o p p e e r r t t y y d d a a m m a a g g e e , ,
m m o o v v e e t t h h e e p p o o w w e e r r s s w w i i t t c c h h t t o o O O F F F F a a n n d d d d i i s s c c o o n n n n e e c c t t m m a a i i n n c c i i r r c c u u i i t t b b r r e e a a k k e e r r , , o o r r u u n n p p l l u u g g
c c o o r r d d a a t t w w a a l l l l r r e e c c e e p p t t a a c c l l e e . .
Remove the lower back shroud.
2 2 ) )
Remove blower (refer to
3 3 ) )
Using an adjustable wrench, remove the flex line from the elbow.(1)
4 4 ) )
Loosen the hose clamp with a flat blade screw driver and disconnect the hose.
5 5 ) )
Use a 3/8" socket or wrench and remove the four nuts and washers (2) from the
6 6 ) )
pumps feet.
Pull the pump off of the studs.
7 7 ) )
Remove the wire nuts.
8 8 ) )
Wire the new pump into the existing wires.
9 9 ) )
Place the pump onto the studs. Be sure to have the shield box (3) in place on
1 1 0 0 ) )
the studs before placing the pump onto studs.
Tighten the pump nuts and washers onto the feet of the pump.
1 1 1 1 ) )
Reconnect fittings.
1 1 2 2 ) )
Replace blower.
1 1 3 3 ) )
48
6.12 Blower Replacement , page
51).