Analog Input 2 - Emotron VS10 Operation Instructions Manual

Hide thumbs Also See for VS10:
Table of Contents

Advertisement

12.14.2. Analog input 2

Settings for analog input 2.
Details
The analog input 2 can be used as setpoint
93
For the process controller, the analog input can be used for the feedback of the variable
(actual value) or speed feedforward control. Basic process controller settings  233
The following settings are possible for the analog input:
• Definition of the input range ①
• Filter time for low-pass filters ②
• Monitoring of the input signal ③
• Dead band for eliminating the smallest signal levels ④
• Definition of the setting range ⑤
Diagnostic parameters:
• The frequency value is displayed in
• The process controller value is displayed in
• The torque value is displayed in
For further details and configuration examples, see chapter
Parameter
Name / value range / [default setting]
0x2637:001
Analog input 2: Input range
(P431.01)
(Analog input 2: AI2 input range)
0 0 ... 10 VDC
1 0 ... 5 VDC
2 2 ... 10 VDC
0x2637:002
Analog input 2: Min frequency value
(P431.02)
(Analog input 2: AI2 freq @ min)
-1000.0 ... [0.0] ... 1000.0 Hz
0x2637:003
Analog input 2: Max frequency value
(P431.03)
(Analog input 2: AI2 freq @ max)
Device for 50-Hz mains: -1000.0 ... [50.0] ... 1000.0 Hz
Device for 60-Hz mains: -1000.0 ... [60.0] ... 1000.0 Hz
0x2637:004
Analog input 2: Min PID value
(P431.04)
(Analog input 2: AI2 PID @ min)
-300.00 ... [0.00] ... 300.00 PID unit
0x2637:005
Analog input 2: Max PID value
(P431.05)
(Analog input 2: AI2 PID @ max)
-300.00 ... [100.00] ... 300.00 PID unit
448
source.Selection of setpoint source
0x2DA5:002
(P111.02).
0x2DA5:003
0x2DA5:004
(P111.04).
(P111.03).
"Analog input
1".
 423
Info
Definition of the input range.
Definition of the setting range for operating mode "MS: Velocity mode".
Direction of rotation according to sign.
The standard setpoint source for operating mode
"MS: Velocity mode [-2]" is selected in
Definition of the setting range for PID control.
The standard setpoint source for the reference value of PID control is
selected in
0x2860:002
(P201.02).
01-6203-01R3, CG Drives & Automation
0x6060 (P301.00)
0x2860:001
(P201.01).
=