Parameter
Name / value range / [default setting]
0x2631:008
Function list: Run forward (CW)
(P400.08)
(Function list: Run forward)
Setting can only be changed if the inverter is
inhibi ted.
For further possible settings, see parameter
0x2631:001
0 Not connected
0x2631:009
Function list: Run reverse (CCW)
(P400.09)
(Function list: Run reverse)
Setting can only be changed if the inverter is
inhibi ted.
For further possible settings, see parameter
0x2631:001
0 Not connected
0x2631:010
Function list: Jog foward (CW)
(P400.10)
(Function list: Jog foward)
Setting can only be changed if the inverter is
inhibi ted.
For further possible settings, see parameter
0x2631:001
0 Not connected
384
(P400.01).
364
(P400.01).
364
(P400.01).
364
Info
Assignment of a trigger for the "Run forward (CW)" function.
Trigger = TRUE: Let motor rotate forward.
Trigger = FALSE: Stop motor.
Notes:
In order to start the motor, "Enable inverter"
and "Run"
0x2631:002 (P400.02)
The inverter always responds to the run command detected last (if
start enable is available).
The stop method can be selected in
In the case of a bipolar setpoint selection (e.g ±10 V), the function is
executed irrespective of the rotating direction. The rotating direction
is determined by the sign of the setpoint.
The "Run forward (CW)" function also serves to realise an automatic
start after switch-on.
Starting performance
No trigger assigned (trigger is constantly FALSE).
Assignment of a trigger for the "Run reverse (CCW)" function.
Trigger = TRUE: Let motor rotate backward.
Trigger = FALSE: Stop motor.
Notes:
In order to start the motor, "Enable inverter"
and "Run"
0x2631:002 (P400.02)
The inverter always responds to the run command detected last (if
start enable is available).
The stop method can be selected in
In the case of a bipolar setpoint selection (e.g ±10 V), the function is
executed irrespective of the rotating direction. The rotating direction
is determined by the sign of the setpoint.
The "Run reverse (CCW)" function also serves to realise an automatic
start after switch-on.
Starting performance
No trigger assigned (trigger is constantly FALSE).
Assignment of a trigger for the "Jog foward (CW)" function.
Trigger = TRUE: Let motor rotate forward with preset 5.
Trigger = FALSE: Stop motor.
CAUTION!
The jog operation has a higher priority than the "Run" function, all other
start commands and the keypad key
If jog operation is active, the motor cannot be stopped with the
previ ously mentioned functions!
However, jog operation can be interrupted by the "Quick stop"
func tion.
Notes:
The preset value 5 can be set in
The stop method can be selected in
If "Jog foward (CW)" and "Jog reverse (CCW)" are activated at the same
time, the motor is stopped using the stop method and jog operation
must be triggered again.
Jog operation cannot be started automatically. The "Start at power up"
option in
0x2838:002 (P203.02)
No trigger assigned (trigger is constantly FALSE).
01-6203-01R3, CG Drives & Automation
0x2631:001 (P400.01)
must be set to TRUE.
0x2838:003
(P203.03).
97
0x2631:001 (P400.01)
must be set to TRUE.
0x2838:003
(P203.03).
97
.
0x2911:005
(P450.05).
0x2838:003
(P203.03).
does not apply to jog operation.