Alarm Reset - Fastech Ezi-Step Plus-R User Manual

Micro stepping system with network based motion controller
Hide thumbs Also See for Ezi-Step Plus-R:
Table of Contents

Advertisement

12.3 Alarm Reset

If an alarm occurs, remove its cause and then release it. The alarm can be released as
follows. In case of alarms of which 'Reset'column is indicated to 'Invalid', power
must get downed prior to releasing the alarms.
Flash
Alarm Name
Count
1
Over Current
Over Speed
2
Step Out
3
Over
5
Temperature
Over
Regenerative
6
voltage
Motor Connect
7
error
Motor Voltage
9
error
11
System error
12
ROM error
Input voltage
14
error
Description
Check the mechanical status such as parameter setting,
motor's
short-circuit,
machine edge is collided), etc.
Check parameter setting, and abnormal operation of the
motor.
Get down the load or increase the acceleration or
deceleration speed.
Get down the ambient temperature or install a cooling
fan.
In
case
of
high-speed
acceleration or deceleration speed is low.
Check the connection status of drive and motor.
Check if power is supplied to the drive.
Check the green LED of CN5.
Check the green LED of CN5.
Check if power is supplied to the drive.
www.fastech.co.kr
12. Protective Function
or
machine
load
(whether
operation,
check
if
the
56
Reset
Valid
Valid
Valid
Valid
Valid
Invalid
Invalid
Invalid
Invalid
Invalid

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ezi-Step Plus-R and is the answer not in the manual?

This manual is also suitable for:

Ezi-step plus-r miniEzi-step-pr-miEzi-step-pr

Table of Contents