SSANGYONG RODIUS 2005.07 Manual page 437

Table of Contents

Advertisement

0-28
6810-20
(1) Inspection
Terminal arrangement
If the air mix door defect error is indicated, check as below.
1.
Turn the ignition switch to ON position.
2.
Measure the voltage between terminal P1 and P2 (approx. 12 V) and terminal a and b
(approx. 5V).
3.
If the voltage value is out of the specified value, check the related circuits for open.
4.
If the circuits are in normal condition, replace the air mix door actuator assembly.
5.
Connect the positive (+) and negative (-) cables of temporary power supply to the air mix
door actuator. And, connect the cable to each terminal (P1 and P2) in turn to check the
motor operation and terminal output.
AIR CONDITIONING SYSTEM
RODIUS 2005.07
Circuit diagram