0-14
8710-01
(3) Speed Sensitive INT (Intermittent) Wiper
For STICS without rain sensor, perform the following operation:
1. Controls the wiper intermittent operation by the values from vehicle speed and volume.
-
Calculates and converts the Intermittent interval automatically by using the vehicle speed
and INT VOLUME when the ignition switch is in "ON"
"ON" position (the engine is running).
-
The wipers are operated in vehicle speed sensitive mode when turning the INT switch
to "ON" position with the engine running or starting the engine with the INT switch
positioned "ON".
Intermittent interval (at 0 km/h): 3 ±
-
2. Vehicle speed calculation
[Input the vehicle speed]
It is calculated by the numbers of input pulses for one second.
1 [pulses/sec] = 60 [km/h] x 60 [sec] / 637 pulses = 1.41 [km/h]
3. VOLUME calculation
-
Calculates the INT VOLUME with 5 grades as shown in the table in next page.
4. Pause time calculation
-
Pause time: the duration that wipers are stopped at parking position
-
Elapsed time: the duration after the wiper motor started to operate from parking position
-
The pause time is calculated by the vehicle speed and VOLUME value as shown in the
table in next page.
·
If the pause time is below 1.0 second, the wipers operate without pause.
·
If the pause time is over 1.5 seconds, the wipers operate intermittently.
STICS
RODIUS 2005.07
position and the INT switch is in
0.5 ~ 19 ± 2 seconds