0-26
6810-20
(1) Inspection
Terminal arrangement
If the intake door mode on FATC is different from the actual intake door mode, check
as below.
1.
Turn the ignition switch to ON position.
2.
Measure the voltage between terminal P1 and P2 (approx. 12 V) and terminal a and b
(approx. 5V).
3.
If the voltage value is out of the specified value, check the related circuits for open.
4.
If the circuits are in normal condition, replace the air door actuator assembly.
5.
If the voltage is within the specified value, replace the mode door actuator assembly.
6.
Connect the positive (+) and negative (-) cables of temporary power supply to the air door
actuator. And, connect the cable to each terminal (P1 and P2) in turn to check the motor
operation and terminal output.
Air source
Fresh air
Recirculation
AIR CONDITIONING SYSTEM
RODIUS 2005.07
Mode
Bc resistance
P1 (-), P2 (+)
below 300 Ω
P1 (+), P2 (-)
over 2.4 kΩ
Circuit diagram