02-8
8511-14
4. Vent Rate Control By Cooling Operation
When the air inside the resonance duct is hot in summer, after the system keeps the low vent
rate (1st) operating for several time and discharges the hot air to the windshield side (Def
Mode), the system starts to control normally in order to avoid for the passengers contacting
the hot air.
5. Defroster Calibration
On the blower AUTO step, when the passenger sets to Defroster (Def), the system increases
the blower voltage by 2 V for some intervals comparing AUTO voltage. But it is excluded the
condition when the blower voltage is above 10.5 V. Also, the voltage increasing by defroster
calibration is limited up to 10.5 V.
3) Vent Inlet Control
1. Manual control
When you push the I/A control switch, you can control the I/A door manually and the I/A door
changes between the recirculation air and the fresh air flow alternately by the control switch.
2. AUTO control
FULL AUTO TEMPERTURE CONTROL