02-44
8710-08
Description of Burglar Alarm Function
1. Armed mode activation requirements
1) The "LOCK" output is "ON" when receiving the "LOCK" signal from transmitter while the
ignition key is removed and all doors are closed. The armed mode is activated when the door
lock switch is locked (hazard relay output: twice).
2) The theft deterrent horn and hazard relay outputs are "ON" when receiving the "LOCK"
signal from the remote control key again in armed mode (hazard relay output: twice).
3) When receiving "LOCK" signal from the remote control key while any of doors is not closed,
only the "LOCK" output can be done and then activates the armed ready mode (without hazard
warning flasher). At this moment, if the ignition key is in the ignition switch, the door unlock
switch is turned "ON" or the door lock switch is unlocked, it cancels the armed mode and
activates the normal mode. However, when closing and locking the opened door, the hazard
warning lamps flash twice.
4) When the door is not opened or the ignition key is not inserted into ignition switch for 30
seconds after receiving "UNLOCK" signal, it outputs "LOCK" and then activates armed mode
(RELOCK operation). Also, at this moment, the system outputs the hazard warning flasher
twice.
5) The armed mode will not be activated except above conditions.
Ex) The armed mode will not be activated when the door is locked by the ignition key.
RKSTICS