Hitachi SJ700D-3 SERIES Quick Reference Manual page 72

Hide thumbs Also See for SJ700D-3 SERIES:
Table of Contents

Advertisement

Chapter 4
List of Data Settings
Code
Function name
H001
Auto-tuning Setting
H002
Motor data selection, 1st motor
H202
Motor data selection, 2nd motor
H003
Motor capacity, 1st motor
H203
Motor capacity, 2nd motor
H004
Motor poles setting, 1st motor
H204
Motor poles setting, 2nd motor
H005
Motor speed constant, 1st motor
H205
Motor speed constant, 2nd motor
H006
Motor stabilization constant, 1st motor
H206
Motor stabilization constant, 2nd motor
H306
Motor stabilization constant, 3rd motor
H020
Motor constant R1, 1st motor
H220
Motor constant R1, 2nd motor
H021
Motor constant R2, 1st motor
H221
Motor constant R2, 2nd motor
H022
Motor constant L, 1st motor
H222
Motor constant L, 2nd motor
H023
Motor constant Io
H223
Motor constant Io, 2nd motor
H024
Motor constant J
H224
Motor constant J, 2nd motor
H030
Auto constant R1, 1st motor
H230
Auto constant R1, 2nd motor
H031
Auto constant R2, 1st motor
H231
Auto constant R2, 2nd motor
H032
Auto constant L, 1st motor
H232
Auto constant L, 2nd motor
H033
Auto constant Io, 1st motor
H233
Auto constant Io, 2nd motor
H034
Auto constant J, 1st motor
H234
Auto constant J, 2nd motor
H050
PI proportional gain for 1st motor
H250
PI proportional gain for 2nd motor
H051
PI integral gain for 1st motor
H251
PI integral gain for 2nd motor
P proportional gain setting for
H052
1st motor
P proportional gain setting for
H252
2nd motor
H060
Zero level limit for 1st motor
H260
Zero level limit for 2nd motor
Zero level starting boost current for 1st
H061
motor
Zero level starting boost current for 2nd
H261
motor
Terminal selection PI proportional gain
H070
setting
H071
Terminal selection PI integral gain setting
Terminal selection P proportional gain
H072
setting
H073
Gain switching time
Monitored data or setting
00 (disabling auto-tuning),
01 (auto-tuning without rotation),
02 (auto-tuning with rotation)
00 (Hitachi standard data), 01 (auto-tuned data),
02 (auto-tuned data [with online auto-tuning function])
0.20 to 160. (kW)
2, 4, 6, 8, 10 (poles)
0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000)
0. to 255.
0.001 to 9.999, 10.00 to 65.53 ()
0.001 to 9.999, 10.00 to 65.53 ()
0.01 to 99.99, 100.0 to 655.3 (mH)
0.01 to 99.99, 100.0 to 655.3 (A)
0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9,
1000. to 9999.
0.001 to 9.999, 10.00 to 65.53 ()
0.001 to 9.999, 10.00 to 65.53 ()
0.01 to 99.99, 100.0 to 655.3 (mH)
0.01 to 99.99, 100.0 to 655.3 (A)
0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9,
1000. to 9999.
0.0 to 999.9, 1000.
0.0 to 999.9, 1000.
0.01 to 10.00
0.0 to 100.0
0. to 50. (%)
0.0 to 999.9, 1000.
0.00 to 10.00
0. to 9999. (ms)
4 - 14
Change during
Default
RUN operation
FF FEF FUF b031≠10
b031=10
00
Not
Not
00
Not
Not
00
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
4
Not
Not
4
Not
Not
1.590
Allowed
Allowed
1.590
Allowed
Allowed
100.
Allowed
Allowed
100.
Allowed
Allowed
100.
Allowed
Allowed
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
Factory setting
Not
Not
100.0
Allowed
Allowed
100.0
Allowed
Allowed
100.0
Allowed
Allowed
100.0
Allowed
Allowed
1.00
Allowed
Allowed
1.00
Allowed
Allowed
100.0
Allowed
Allowed
100.0
Allowed
Allowed
50.
Allowed
Allowed
50.
Allowed
Allowed
100.0
Allowed
Allowed
100.0
Allowed
Allowed
1.00
Allowed
Allowed
100.
Allowed
Allowed