Hitachi SJ700D-3 SERIES Quick Reference Manual page 66

Hide thumbs Also See for SJ700D-3 SERIES:
Table of Contents

Advertisement

Chapter 4
List of Data Settings
Code
Function name
b034
Run/power-on warning time
b035
Rotational direction restriction
b036
Reduced voltage start selection
b037
Function code display restriction
b038
Initial-screen selection
Automatic user-parameter setting
b039
function enable
b040
Torque limit selection
Torque limit (1)
b041
(forward-driving in 4-quadrant mode)
Torque limit (2)
b042
(reverse-regenerating in 4-quadrant mode)
Torque limit (3)
b043
(reverse-driving in 4-quadrant mode)
Torque limit (4)
b044
(forward-regenerating in 4-quadrant mode)
b045
Torque limit LADSTOP enable
b046
Reverse Run protection enable
b049
Dual rating selection
Controller deceleration and stop on power
b050
loss
DC bus voltage trigger level during power
b051
loss
b052
Over-voltage threshold during power loss
b053
Deceleration time setting during power loss
Initial output frequency decrease during
b054
power loss
Proportional gain setting for nonstop
b055
operation at power loss
Integral time setting for nonstop operation
b056
at power loss
Maximum-limit level of window
b060
comparators O
Minimum-limit level of window
b061
comparators O
b062
Hysteresis width of window comparators O
Maximum-limit level of window
b063
comparators OI
Minimum-limit level of window
b064
comparators OI
Hysteresis width of window comparators
b065
OI
Maximum-limit level of window
b066
comparators OI
Minimum-limit level of window
b067
comparators O/OI/O2
Hysteresis width of window comparators
b068
O/OI/O2
b070
Operation level at O disconnection
b071
Operation level at OI disconnection
b072
Operation level at O2 disconnection
(Note) < > indicate the setting range of 75 to 150kW
(Note) CT : Constant torque mode, VT : variable torque mode, you can set CT or VT by b049.
*) In case of connecting OPE-S to the inverter, '201' setting is same as '00' setting. Refer to the SJ700D-3 instruction manual.
Monitored data or setting
0. to 9999. (0 to 99990),
1000 to 6553 (100000 to 655300) (hr)
00 (enabling both forward and reverse rotations),
01 (enabling only forward rotation),
02 (enabling only reverse rotation)
0 (minimum reduced voltage start time) to
255 (maximum reduced voltage start time)
00 (full display), 01 (function-specific display),
02 (user setting), 03 (data comparison display), 04 (basic display)
00 (screen displayed when the STR key was pressed last),
001~060 (d001~d060), 201 (F001) 202 *)
00 (disabling), 01 (enabling)
00 (quadrant-specific setting), 01 (switching by terminal),
02 (analog input), 03 (option 1), 04 (option 2)
0. to 200. (%), no (disabling torque limitation)
<0. to 150. (%), no (disabling torque limitation)> (In case of CT)
0. to 150. (%), no (disabling torque limitation)(In case of VT)
00 (disabling), 01 (enabling)
00 (disabling), 01 (enabling)
00 (CT : Constant torque)
01 (VT : Variable torque)
00 (disabling), 01 (nonstop deceleration to stop),
02 (DC voltage constant control, with resume),
03 (DC voltage constant control, without resume)
0.0 to 999.9, 1000. (V)
0.0 to 999.9, 1000. (V)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.00 to 10.00 (Hz)
0.00 to 2.55
0.000 to 9.999 /10.00 to 65.53 (s)
0. to 100. (lower limit : b061 + b062 x 2) (%)
0. to 100. (upper limit : b060 - b062 x 2) (%)
0. to 10. (upper limit : b060 - b061 / 2) (%)
0. to 100. (lower limit : b064 + b065 x 2) (%)
0. to 100. (upper limit : b063 - b064 x 2) (%)
0. to 10. (upper limit : b063 - b064 / 2) (%)
-100. to 100. (lower limit : b067 + b068 x 2) (%)
-100. to 100. (upper limit : b066 - b068 x 2) (%)
0. to 10. (upper limit : b066 - b067 / 2) (%)
0. to 100. (%) or "no" (ignore)
0. to 100. (%) or "no" (ignore)
-100. to 100. (%) or "no" (ignore)
4 - 8
Change during
Default
RUN operation
FF FEF FUF
b031≠10
b031=10
0.
Not
Allowed
00
Not
Not
6
Not
Allowed
00
Not
Allowed
001
Not
Allowed
00
Not
Allowed
00
Not
Allowed
150.(CT)
Not
Allowed
120.(VT)
150.(CT)
Not
Allowed
120.(VT)
150.(CT)
Not
Allowed
120.(VT)
150.(CT)
Not
Allowed
120.(VT)
00
Not
Allowed
00
Not
Allowed
00(CT)
Not
Not
01(VT)
00
Not
Not
220.0/440.0
Not
Not
360.0/720.0
Not
Not
1.00
Not
Not
0.00
Not
Not
0.20
Allowed Allowed
0.100
Allowed Allowed
100
Allowed Allowed
0
Allowed Allowed
0
Allowed Allowed
100
Allowed Allowed
0
Allowed Allowed
0
Allowed Allowed
100
Allowed Allowed
-100
Allowed Allowed
0
Allowed Allowed
no
Not
Allowed
no
Not
Allowed
no
Not
Allowed

Advertisement