Hitachi SJ700D-3 SERIES Quick Reference Manual page 70

Hide thumbs Also See for SJ700D-3 SERIES:
Table of Contents

Advertisement

Chapter 4
List of Data Settings
Code
Function name
Low-current indication signal output mode
C038
selection
C039 Low-current indication signal detection level
C040 Overload signal output mode
C041 Overload level setting
C042 Frequency arrival setting for accel.
C043 Frequency arrival setting for decel.
C044 PID deviation level setting
C045 Frequency arrival setting for acceleration (2)
C046 Frequency arrival setting for deceleration (2)
C052 Maximum PID feedback data
C053 Minimum PID feedback data
C055 Over-torque (forward-driving) level setting
Over-torque (reverse regenerating) level
C056
setting
C057 Over-torque (reverse driving) level setting
Over-torque (forward regenerating) level
C058
setting
C061 Electronic thermal warning level setting
C062 Alarm code output
C063 Zero speed detection level
C064 Heat sink overheat warning level
C071 Communication speed selection
C072 Node allocation
C073 Communication data length selection
C074 Communication parity selection
C075 Communication stop bit selection
Selection of the operation after
C076
communication error
C077 Communication timeout limit before tripping 0.00 to 99.99 (s)
C078 Communication wait time
C079 Communication mode selection
C081 [O] input span calibration
C082 [OI] input span calibration
C083 [O2] input span calibration
C085 Thermistor input tuning
C091 Debug mode enable
C101 Up/Down memory mode selection
C102 Reset mode selection
C103 Restart mode after reset
C105 FM gain adjustment
C106 AM gain adjustment
C107 AMI gain adjustment
C109 AM bias adjustment
C110 AMI bias adjustment
(Note) < >indicate the setting range of 75 to 150kW
(Note) CT : Constant torque mode, VT : variable torque mode, you can set CT or VT by b049.
Monitored data or setting
00 (output during acceleration/deceleration and constant-speed
operation),
01 (output only during constant-speed operation)
0.00 to 2.00 x "rated current" (A)
<0.00 to 1.80 x "rated current" (A) > (In case of CT)
0.00 to 1.50 x "rated current" (A) (In case of VT)
00 (output during acceleration/deceleration and constant-speed
operation),
01 (output only during constant-speed operation)
0.00 to 2.00 x "rated current" (A)
<0.00 to 1.80 x "rated current" (A) > (In case of CT)
0.00 to 1.50 x "rated current" (A) (In case of VT)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.0 to 100.0 (%)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.0 to 100.0 (%)
0.0 to 100.0 (%)
0. to 200. (%), no (disabling torque limitation)
<0. to 150. (%), no (disabling torque limitation)> (In case of CT)
0. to 150. (%), no (disabling torque limitation)(In case of VT)
0. to 100. (%)
00 (disabling), 01 (3 bits), 02 (4 bits)
0.00 to 99.99, 100.0 (Hz)
0. to 200.0 (C)
02 (loopback test), 03(2400bps), 04(4800bps),
05(9600bps), 06(19.2kbps), 07(38.4kbps),
08(57.6kbps), 09(76.8kbps), 10(115.2kbps)
1. to 32.
7 (7 bits), 8 (8 bits)
00 (no parity), 01 (even parity), 02 (odd parity)
1 (1 bit), 2 (2 bits)
00 (tripping),
01 (tripping after decelerating and stopping the motor),
02 (ignoring errors),
03 (stopping the motor after free-running),
04 (decelerating and stopping the motor)
0. to 1000. (ms)
00(ASCII), 01(Modbus-RTU)
0. to 9999., 1000 to 6553(10000 to 65530)
0.0 to 999.9, 1000.
(Do not change this parameter, which is intended for factory
adjustment.)
00 (not storing the frequency data),
01 (storing the frequency data)
00 (resetting the trip when RS is on),
01 (resetting the trip when RS is off),
02 (enabling resetting only upon tripping [resetting when RS is
on]), 03(resetting only trip)
00 (starting with 0 Hz), 01 (starting with matching frequency),
02 (restarting with active matching frequency)
50. to 200. (%)
0. to 100. (%)
4 - 12
Change during
Default
RUN operation
FF FEF FUF b031≠10
b031=10
01
Not
Allowed
Rated
Allowed
Allowed
current
01
Not
Allowed
Rated
Allowed
Allowed
current
0.00
Not
Allowed
0.00
Not
Allowed
3.0
Not
Allowed
0.00
Not
Allowed
0.00
Not
Allowed
100.0
Not
Allowed
0.0
Not
Allowed
100.
Not
Allowed
100.
Not
Allowed
100.
Not
Allowed
100.
Not
Allowed
80.
Not
Allowed
00
Not
Allowed
0.00
Not
Allowed
120.
Not
Allowed
04
Not
Allowed
1.
Not
Allowed
7
Not
Allowed
00
Not
Allowed
1
Not
Allowed
02
Not
Allowed
0.00
Not
Allowed
0.
Not
Allowed
00
Not
Allowed
Factory
Allowed
Allowed
setting
Factory
Allowed
Allowed
setting
Factory
Allowed
Allowed
setting
Factory
Allowed
Allowed
setting
00
Not
Not
00
Not
Allowed
00
Allowed
Allowed
00
Not
Allowed
100.
Allowed
Allowed
100.
Allowed
Allowed
100.
Allowed
Allowed
0.
Allowed
Allowed
20.
Allowed
Allowed